Quick Start Guide Version 1.1
Atop ABLELink
®
Wireless Serial Server
SW2001SW5001
3
Configure by Telnet utility
Step 1:Telnet to SW2001/SW5001 using command “Telnet IP_address”. Default IP address is
10.0.50.100 and default password is null.
Step 2:SW2001/SW5001’s network, COM ports and wireless settings can be configured
individually.
Step 3:The connection status is shown from “AP version” column of monitoring tool (Monitor.exe)
.
4. Pin assignments
Pin assignments of Mini DIN connector is shown in the following table:
Mini-DIN DB9
Pin# RS-232 2 wire RS-485 4 wire RS-485
1
DCD
2
RXD Tx+
3
TXD Data+ Rx+
4
DTR
5
SG (Signal Ground)
6
DSR
7
RTS Data- Rx-
8
CTS Tx-
Pin assignments for Terminal block for Serial and Power
5-pin for serial connections
RS-232 RS-485 RS-422
3-pin for Power input
SG GND GND GND FG GND
RTS/R- RTS Data- R- Vin- 0V
TxD/R+ TxD Data- R+ Vin+ 9~30V
CTS/T- CTS T-
RxD/T+ RxD T+